Voltesta

Precharge circuits: why you can't just close the contactor

, 1 min read

In a high-voltage EV, you cannot simply slam the battery onto the controller. Doing so causes a huge inrush of current.

The inrush problem

The controller has large capacitors that are empty at start-up. Connecting the full pack straight to them is like opening a tap onto an empty tank: a massive surge flows for an instant. That surge can weld the contactor contacts shut, which is dangerous because the pack can then never be disconnected.

How precharge solves it

A precharge circuit first connects the pack through a resistor, which limits the current and lets the capacitors fill gently over a fraction of a second. Once they are nearly full, the main contactor closes with almost no surge, and the resistor path opens.

A typical sequence: close the precharge relay (pack to caps through a resistor), wait until the capacitor voltage is within a few percent of pack voltage, close the main contactor, then open the precharge relay.

Skipping or breaking the precharge is a common cause of welded contactors and tripped systems.